    UHV-905 Automatic CT PT Transformer Calibrate System PT Transformer calibrator Test Set Instrument

    UHV-905 Automatic CT PT Transformer Calibrate System PT Transformer calibrator Test Set Instrument is used for PT, CT error and impedance, admittance test. With the perfect combination of advanced and unique circuit and DSP technology, the unstable problem of resistance-capacitance phase-shifting circuit is completely eliminated.

    Product Details of UHV-905 Automatic CT PT Transformer Calibrate System PT Transformer calibrator Test Set Instrument

    CT PT Calibrate System

    Equipment operating environment

    temperature5℃~40

    relative humidity℃时)

    altitude

    mains frequency50Hz±0.5Hz

    mains input220V±5V

    range of measurement

    cophase component(%)0.0001200.0

    distinguishability0.0001

    orthogonal component(part)0.001700.0

    distinguishability0.001

    impedance(Ω)0.000120.0

    distinguishability0.0001

    admittance(ms)0.000120.0

    distinguishability0.0001

    intrinsic error

    cophase component

    ΔX=±(X×2%Y×2%)±Dx(Level 1 is optional)

    orthogonal component

    ΔY=±(X×2%Y×2%)±Dy(Level 1 is optional)

    "X""Y"——Display value of instrument

    "Dx,Dy"——Display value of instrument

    Dx=2Dy=5

    dial indicator

    PETS2(Level 1 is optional)

    working range

    electricity

    (1%149%)In (In =5A)

    (5%149%)In (In =1A)

    voltage

    (5%149%)Un (Un =100V150V100V/)

    (5%149%)Un (Un =100V/3)

    workload

    electricity

    TO to TX0.12ΩcosΦ=1

    voltage

    a to x0.25VA (100V)

    Polarity error indication

    When the operating current (voltage) reaches more than 5% of the rated current (voltage) and the error exceeds 180%, there should be polarity indication.

    Note: if it is more than 10% of the rated operating current (voltage), there is still no proper polarity indication, indicating a fault. Please do not increase the current (voltage) to avoid burning out the instrument.

    Variable ratio error indication

    When the operating current (voltage) reaches more than 5% of the rated current (voltage) and the error exceeds 30% but is less than 180%, the error indication of variable ratio should be given.

    Insulation and voltage test and

    instructions

    terminalTX()Terminal is same

    The power socket can withstand the housing1.5kV1minwithstand voltage

    NicknameCT PT Calibrate SystemCT Transformer calibratorPT Transformer calibrator

    Features

    1. The intelligent transformer calibrator uses 320×240 dot-matrix liquid crystal, with a large viewing range and long-life backlight illumination, which is convenient to use

    2. Full Chinese operation interface, beautiful interface

    3. The dial indicator, ratio difference and angle difference are displayed in extra large font, which is convenient for users to observe

    4. The intelligent transformer calibrator produced by our company fully meets the requirements of JJG314-1993 and JJG314-1994, and automatic sampling

    5. Automatic judgment of wrong polarity and wrong ratio

    6. The host computer software has the function of opening virtual instruments

    7. Completely solve the S-level measurement problem

    8. Automatic switching range

    9. Adopt the perfect combination of advanced unique circuit and DSP technology to completely remove the problem of instability of the resistance-capacitance phase-shift circuit

    10. Power consumption:

    11. Harmonic suppression ratio: >40db

    12. Overall dimensions (L×W×H): 260×350×150mm3

    13. Weight: 6kg