qiao@hvtest.cc15871365102
  • کیت تست دی سی هیپوت تستر ژنراتور ولتاژ بالا DC 200 ~ 400 کیلوولت ZGF

    تستر Hipot DC سری 200 کیلو ولت 300 کیلو ولت 400 کیلو ولت به طور عمده توسط میزبان اصلی کنترل، سیلندر دوبرابر ولتاژ، حلقه کرونا و غیره تشکیل شده است. می تواند تست مقاومت ولتاژ بالا DC و تست جریان نشتی را برای برقگیر سوپاپ، ترانسفورماتور قدرت، 35-500 کیلوولت انجام دهد. و برقگیر اکسید روی

    جزئیات محصول از کیت تست دی سی هیپوت تستر ژنراتور ولتاژ بالا DC ZGF 200~400kV


    ZGF DC Hipot Tester

    معرفی محصول

    The ZGF DC Hipot Tester manufactures is a specialized high-voltage generating equipment designed for on-site testing in the power equipment field. dc hipot tester features reliable protection functions, including overvoltage, overcurrent, and zero-closing protection, and provides accurate 0.75 times output voltage indication for precise measurement and control.


    Technical characteristics and advantages of DC high-voltage generator

    Stable output: using high-frequency voltage doubling circuit or intermediate frequency inverter technology, with small voltage fluctuations and high testing accuracy.

    Protection function: Equipped with overvoltage, overcurrent, zero start, grounding protection, etc., to ensure safe operation.

    Portability and Integration: The miniaturized design facilitates on-site use, and some models integrate control, measurement, and protection functions into one.


    DC Hipot Test Kit 2
    DC Hipot Test Kit 3


    Technical Parameters

    مشخصات فنی200/2200/3200/5300/2300/3300/5400/2400/3400/5
    ولتاژ نامی (کیلوولت)200200200300300300400400400
    جریان نامی (میلی آمپر)235235235
    توان نامی (وات)4006001000600900150080012002000
    Control box quality(kg)5.56.06.510.510.510.510.510.510.8
    Pressure cylinder quality(kg)8.799242424.533.533.533.5
    ارتفاع سیلندر دوتایی (میلی‌متر)970970970125012501250165016501650
    دقت ولتاژ± (1.0% خواندن + 2 کلمه)
    دقت فعلی± (1.0% خواندن + 2 کلمه)
    ضریب ریپل≤0.5%
    پایداری ولتاژهنگامی که ولتاژ منبع تغذیه ± 10% ≤1% تغییر می کند
    قابلیت اضافه بارولتاژ بدون بار می تواند به مدت 10 دقیقه از 10٪ ولتاژ نامی تجاوز کند
    حداکثر جریان شارژ 1.25 برابر جریان نامی است
    منبع تغذیهارتباط تک فاز 50 هرتز 220 ولت ± 10 درصد
    شیوه ی کاراستفاده متناوب: بار نامی 30 دقیقه
    1.1 بار مصرف ولتاژ نامی: 10 دقیقه
    شیوه ی کارtemperature:-10℃~+40℃
    Relative humidity: no more than 85% at room temperature of 25 °C (no condensation)
    ارتفاع: زیر 1500 متر
    با ظرفیت بار خازنیمحصول تست شده دارای ظرفیت نامحدود است
    با جریان نامی 1.5 برابر شارژ می شود
    ویژگی های ساختاریElectrical insulation doubler
    عایق هوا، بدون نشتی
    ویژگی های جعبه عملیاتیدکمه تک لمسی با دقت بالا 0.75UDC1mA (دقت ≤1.0%)، مناسب برای تست رعد و برق گیر اکسید روی
    حفاظت از اضافه ولتاژ با استفاده از کلید شماره گیری دیجیتال، در یک نگاه
    شاسی قابل حمل، راحت تر در محل


    دامنه کاربرد

    1. Conductivity current test of valve type lightning arrester.

    2. DC withstand voltage test and leakage current measurement of power transformers.

    3. تست ولتاژ مقاومت DC و اندازه گیری جریان نشتی کابل های ولتاژ بالا (35-500 کیلو ولت و کمتر).

    4. U1mA DC reference voltage test and 0.75U1mA leakage current test for zinc oxide lightning arrester.


    DC Hipot Test Kit 5
    DC Hipot Test KitDC Hipot Test Kit 4


    Core application scenarios

    1、Insulation performance testing of power equipment

    1. Voltage withstand test of high-voltage electrical equipment

    Transformer: Test the insulation strength of the winding to ground and between layers to ensure that there is no risk of breakdown during long-term operation at rated voltage.

    Switchgear: Detect the insulation reliability of components such as contacts and insulators under high voltage, and prevent partial discharge or breakdown accidents.

    Transformer: Verify the electrical performance of insulation materials in high voltage environments, ensuring measurement accuracy and equipment safety.

    2. DC reference voltage test for lightning arrester. Measure the leakage current of lightning arrester under DC voltage, evaluate its nonlinear resistance characteristics, and ensure the normal overvoltage protection function.

    2、Cable and accessory testing

    1. DC withstand voltage test for power cables. Detect the voltage resistance of the main insulation of the cable (such as cross-linked polyethylene) under high DC voltage, and discover manufacturing defects or aging damage.

    2. Performance verification of cable accessories. Test the insulation performance of cable terminals and intermediate joints to ensure that there is no partial discharge or breakdown at the joint location under high voltage.

    3、Testing of Insulation Materials and Components

    1. Inspection of high-voltage components such as insulators and bushings. Apply high DC voltage, measure leakage current, evaluate surface hydrophobicity, pollution tolerance, and internal defects of insulators.

    2. Dielectric loss test of capacitors. By measuring the capacitance and dielectric loss tangent (tan δ) under high DC voltage, the degree of dielectric aging of capacitors can be determined.

    4、Special industry applications

    1. Detection of electrified railway contact network. Test the voltage resistance performance of components such as contact line insulators and section insulators to ensure the safety of train power supply.

    2. Testing of new energy equipment. Used for insulation performance verification of photovoltaic inverters, wind power converters and other equipment to ensure their reliability in complex power grid environments.


    Frequently Asked Questions

    Q: What is the difference between a DC high-voltage generator and an AC high-voltage generator?
    A: DC high-voltage generator outputs a stable, constant direct current and is mainly used for DC withstand voltage tests. An AC high-voltage generator, on the other hand, outputs alternating current and is mainly used for AC withstand voltage tests, with a different approach to assessing insulation performance.
    Q: What safety precautions should be taken when using DC high-voltage generator?
    A: Ensure that the equipment is properly grounded, and that operators wear insulating shoes and insulating gloves and stay well away from the high-voltage output terminals. During testing, a supervisor should be present, and all personnel should be familiar with emergency response procedures.
    Q: How can I judge the quality of a DC high-voltage generator?
    A: It can be evaluated in terms of output voltage stability, ripple factor, overload capacity, insulation performance, and the sensitivity of its protection functions.
    Q: What materials can be tested with a DC high-voltage generator?
    A: dc hipot tester can be used for various insulating materials, such as plastics, rubber, ceramic parts, oil‑impregnated paper, etc., as well as for DC insulation performance testing on high‑voltage electrical equipment like power cables, transformers, and instrument transformers.







    شما همچنین ممکن است دوست داشته باشید

    • ما را ملاقات کنید

      ساختمان 6، پارک صنعتی مکانیکی نوری اپتیک ولی، 84 جاده Gaoxin 5،
      منطقه توسعه فناوری جدید دریاچه شرقی، شهر ووهان، استان هوبی، چین

    • به ما ایمیل بزنید

      qiao@hvtest.cc

    • با ما تماس بگیرید

      +86-15871365102